Download Print this page

Installation; Screw Mounting - Omron K6CM Startup Manual

Motor condition monitoring device
Hide thumbs Also See for K6CM:

Advertisement

5
Step

Installation

DIN Rail Mounting
There is no particular restriction on the mounting direction of the K6CM device, but install it securely in the horizontal or
vertical direction as much as possible.
(1) On the rear surface of the unit, release the DIN rail mounting pins.
(2) To mount the K6CM device to a DIN Track, hook the device onto the DIN Track and press the device in the direction of
the arrow until you hear it lock into place.
[1]
(3) Lock all DIN rail mounting pins.
Note1. Affix the DIN rail in three or more places using screws.
Note2. DIN rail: PFP-50N (500 mm)/PFP-100N (1000 mm)

Screw Mounting

When installing the product using screws, first drill screw holes using the dimensions in the figure below, then tighten
using specified-size screws and flat washers to the correct torque. The product does not come with mounting screws. Use
commercially available screws.
Screw types and lengths will differ depending on the mounting location materials and thickness, therefore ensure screws that
meet these conditions are used.
(1) Pull out 2 hooks in the K6CM device back outside until sound will be.
(2) Insert M3 screw in a hole of a hook and fix.
• Used screws: M3×2 locations
• Recommended tightening torque: 0.5 to 0.6 N•m
Screw
Mounting Hole Dimensions
Two, M3 holes or
Two, 3 dia.
24
[2]
(2)
108 mm
(2)
Mounting Hole Dimensions
(1)
Two, M3 holes or
Two, 3 dia.
(1)
108 mm

Advertisement