NLTroubleshooting
Malfunction
"E:36 / -10"
"E:60 / -2B"
"E:30 / -10" and/or
flashes.
42
Cause and Troubleshooting
Remove any unauthorized extensions from the
water drain hose.
"Connecting the device", page 15
Pump cover is not fully screwed in.
Make sure that the pump cover is screwed into the
device as far as it will go. The pump cover handle
must be vertical.
The unbalance detection system has interrupted the
spin cycle due to uneven distribution of the laundry.
Redistribute the laundry in the drum.
Remark:If possible, place large and small items of
laundry together in the drum. Different sized laundry
is more evenly distributed during the spin cycle.
Water pressure is low.
No solution possible.
The strainers in the water supply are clogged.
▶ Clean the strainers in the water supply.
Water tap is closed.
Open the water tap.
Water supply hose is kinked or pinched.
Make sure that the water supply hose is not
kinked or pinched.
Water level measuring system defective.
Remark:With the error message, the device starts a
pump-down procedure.
First, wait for approx. 5 minutes until the pump-down procedure
1.
has ended.
To reset the error message, turn off the device.
2.
Turn the device back on.
3.
If the error message appears again, please contact
4.
customer service.
"Customer Service", page 51
The Voltage Control System detects an impermissible
voltage drop.
No solution possible.
Remark:When the supply voltage has stabilized, the
program continues normally.