30
PERIODIC SERVICE
A If the dust cup is mounted incorrectly, dust or dirt will
not collect in the cup and allow the dust to come into
direct contact with the element and thus require the
element be replaced prematurely.
(1) Air cleaner body
(2) Secondary element
(3) Primary element
(4) Dust cup
(5) "TOP" mark
(6) Evecuator valve
C Air Cleaner with Dust Cup
Remove and clean out the dust cup once a week under
normal conditions or daily in extreme conditions.
Do not allow the dust cup to fill above half way regard-
less of conditions.
Install the air cleaner dust cup with "TOP" indicated on
the rear of the cup in the upward position with horizon-
tally mounted air cleaner bodies or vertically mounted
air cleaner bodies, the cup may be mounted in any di-
rection.
B Radiator
Make it a rule to check the coolant level before every op-
eration.
CAUTION
To avoid personal injury:
A DO NOT stop the engine suddenly,
stop it after about 5 minutes of
unloaded idling.
A Work only after letting the engine
and radiator cool off completely
(more than 30 minutes after it has
been stopped).
A DO NOT remove the radiator cap
while coolant is hot. When cool,
rotate cap slowly to the first stop to
allow excess pressure to escape.
Then remove cap completely.
If overheating should occur, steam
gushes out from the radiator or
reserve tank; Allow the engine to
cool before attempting to open the
cap. Severe burns could result.
C Checking coolant level, adding coolant
1. Remove the radiator cap after the engine has
completely cooled, and check to see that coolant
reaches the supply port.
(1) Radiator cap
(2) Coolant filling port

Hide quick links:

Advertisement

Table of Contents
loading