CITL_EnableYInt
This function enables the routine registered with the CITL_EntryYInt function.
■ Format
short CITL_EnableYInt (short sYNo)
■ Argument
Argument
Name
sYNo
Output signal (Y) number
■ Description
• This function enables the routine registered with the CITL_EntryYInt function. (The routine is executed when an output
signal (Y) interrupt occurs.)
• Specify the output signal (Y) number (sYNo) specified in the CITL_EntryYInt function in the output signal (Y) number
(sYNo).
• The output signal (Y) interrupt event notification wait function (CITL_WaitYEvent function)and the function executing
interrupt routine when output signal (Y) interrupts (Defined by CITL_EntryYInt/CITL_EnableYInt/CITL_DisableYInt function)
operate independently. These functions operate independently even if interrupt occurs by the same output signals (Y).
■ Return value
Return value
Description
0 (0000H)
Normal
Other than 0 (0000H)
Error
For details on the error, refer to the following chapter.
Page 108 ERROR CODE LIST
■ Relevant function
Page 24 CITL_DisableYInt
Page 30 CITL_EntryYInt
Description
Specify the output signal (Y) number.
(If -1 is specified, enable all the registered routines.)