E R R O R C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODES
Rotating Gobo
Rotation Er
xed Gobo
Wheel Er
Prism Wheel 1 Er
Prism Rotation
Wheel 1 Er
Prism Wheel 2 Er
Prism Rotation
Wheel 2 Er
Focus Er
Zoom Er
DESCRIPTION
The Rotating Gobo rotation movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
The Fixed Gobo Wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel's magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Prism Wheel 1movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel's magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Prism Wheel 1 rotation movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
The Prism Wheel 2 movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel's magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Prism Wheel 2 rotation movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).
The Focus movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Zoom movement is not located in the default position after the reset. This
message will appear after a fixture reset if the gobo wheel's magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).