Konica Minolta CS-3 Operation Manual page 39

Regius console
Hide thumbs Also See for CS-3:
Table of Contents

Advertisement

Ch.3 Sequence of Examination
Automatic Confirmation Function
In cases where there is an automatic confirmation function, after a cer-
tain time has elapsed from reading the image with a green frame
around the order, the confirmation process will be judged to be com-
pleted and the image will be output.
This function is not available in the examination check screen (multiple-
image format).
• The [OK] button displays time remaining (secs.) until the order
is confirmed automatically.
Following this screen:
Outputting the image
Select the target
order from the order
list.
Amending patient data
Amending exposure parameters/
Adding or deleting the order
Amending image processing
Select the target
order from the
order list.
Amending print format
Select the target
order from the
order list.
Amending overlay
Select the target
order from the
order list.
REGIUS Console CS-3 OPERATION MANUAL Ver. 1.10 2005.2
3
Position the reader device to match the patient.
• If it is necessary to alter size, angle or position,
use the panel switches on the reader device or
touch the image display field on the CS-3
Operation Unit to select them on the detailed data
selection screen.
• For details of operation of the reader device, refer
to the reader device operation manual.
4
Depress the exposure button on the X-ray gener-
ator.
• The image read by the reader will be displayed in
the image display field.
• The S-value of the image read will be displayed
below the image display field.
• The green frame will move to the next order on the
order list.
5
1
4
Repeat steps
~
each of the orders on the order list.
Touch
Touch
Touch
Image
Display
Field
Touch
Image
Display
Field
Touch
Image
Display
Field
Touch
< 37 >
to execute exposure for
Image
Processing
Touch
Print
Format
Touch
Overlay
Touch
Whenever the examina-
tion is started and the
device is switched to
another device, an era-
sure will be carried out.
In order to carry out the
examination smoothly,
it is recommended that
order selection be
made prior to position-
ing the patient for expo-
sure when using the
upright position reader.
p.45, 46
Image Output
[Single-Image Format]
p.95
Patient Data
Amendment Screen
p.98
Body Part/ Parameter
Selection Screen
p.103
Detailed Data
Setting Screen
(Image Processing)
p.111
Detailed Data
Setting Screen
(Print Format)
p.118
Detailed Data
Setting Screen
(Overlay)

Advertisement

Table of Contents
loading

This manual is also suitable for:

0862

Table of Contents