18HEK03 Introduction 2. Introduction 2.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
18HEK03 Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Page 6
18HEK03 Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
18HEK03 Introduction 2.1.3 Inspection after Repair Warning Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet all the way. If the plug has dust or loose connection, it can cause an electrical shock or fire. If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
18HEK03 Introduction 2.1.4 Using Icons Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below: 2.1.5 Using Icons List Icon Type of Information Description A “note” provides information that is not indispensable, but may Note: Note nevertheless be valuable to the reader, such as tips and tricks.
18HEK03 4.Printed Circuit Board Connector Wiring Diagram 4.1 Indoor unit Connectors Indoor PCB 1)CN1connector for transformer input 2)CN2 connector for terminal block. 3)CN3 connector for transformer output 4)CN5” or CN5”(1) connector for up and down step motor. 5)CN6 connector for ambient temp. sensor and piping temp.sensor. 6)CN7 connector for receiver display.
18HEK03 5 Functions and control 5.1 main functions and control specifications Including brief introduction to air conditioners of series models and electric control function. 5.1.1 Automatic running Automatic running mode When the running mode is turned to automation after starting the system, the system will first determine the running mode according to the current room temperature and then will run according to the determined mode.
Page 13
18HEK03 Manual operation:When unit is on the wind speed can be set to high, medium, low or automatic as required (execute instruction 2 seconds later after receiving remote signal) Compressor control The compressor can’t be controlled by temperature sensor within 2 minutes after start up and can be only restarted at least 3 minutes later after shutdown.
Page 14
18HEK03 5.1.5.3.1 Entry conditions of defrosting: The entry conditions of defrosting is classified into two types: intelligentized defrosting and sensor defrosting. Through selecting and judging, the models without outdoor sensor defrosts according to intelligentized defrosting, and others with ensor defrosts according to sensor defrosting. Intelligentized defrosting: 5.1.5.3.1.1 Indoor unit enter overload protection and air outlet stops when air outlet has been restarted and runs over 10 minutes, and compressor runs over 45 minutes in total and over 20 minutes...
Page 15
18HEK03 5.1.5.3.1 Entry conditions of defrosting: The entry conditions of defrosting is classified into two types: intelligentized defrosting and sensor defrosting. Through selecting and judging, the models without outdoor sensor defrosts according to intelligentized defrosting, and others with ensor defrosts according to sensor defrosting. Intelligentized defrosting: 5.1.5.3.1.1 Indoor unit enter overload protection and air outlet stops when air outlet has been restarted and runs over 10 minutes, and compressor runs over 45 minutes in total and over 20 minutes...
Page 16
18HEK03 5.1.6.2 Timer off: Unit starts, timer indicator lights up; When reaching time setting, the indicator goes out, unit enters shut down mode, and sleep function can be set. If timer off and sleep are set synchronously, the one which time is short run first. Executing shutdown instruction clear timer and sleep function.
18HEK03 Current cross control doesn’t work. The control of current cross peak expiration doesn’t work. Temperature control doesn’t work. Temperature expiration control doesn’t work. 5.1.10 memory function The memory function of power down is available, and the auto recovery function of power on is optional. (In auto, heating, cooling, or defrosting status, press the “sleeping” button 10 times within 5 seconds, and the auto recovery function of power on can be set on/off.
18HEK03 Parts and Functions Indoor Unit Remote controller 6. SIGNAL SENDING 7. TIMER OFF display 8. TIMER ON display 9. CLOCK display 10. TEMP display HEALTH ON/OFF 11. POWER ON/OFF Used for unit start and stop. 12. MODE Used to select AUTO run, COOL, DRY,HEAT and FAN operation.
18HEK03 Operation Unit start / stop Auto Operation Press ON/OFF button, unit starts or stops. According to the automatic choice HEALTH ON/OFF system in temperature in indoors cold or make the hot movement MODE Select temp.setting SWING MODE SWING Remote Operation Note Dry Operation...
Page 33
18HEK03 Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and installation of the power source...
18HEK03 7.Codes and Description 7.1.Problem Symptoms and Measures Symptom Check Item Details of Measure Check to make sure that the rated voltage is Check the power supply. None of the units supplied. operates Check the indoor PCB Check to make sure that the indoor PCB is broken Equipment operates but does Diagnosis...
Page 35
18HEK03 Pull the sensor out of the mainboard Measure the value of resistance Between its two jumpers Measure the temperature at the room temperature sensing head. Check the value of the Sensor is broken,replace it with new sensor sensor to see whether the sensor is damaged or not? The indoor PCB is broken, replace with new indoor PCB E4 Indoor EEPROM error: Replace the PCB of indoor unit...
Page 36
18HEK03 E14 :Indoor fan motor malfunction Notes: When the unit is on ,don’t pull out or insert the terminal of the motor (CN9), or else The motor would be damaged. whether terminal CN8 Pull out and reinsert the terminals and CN9 on indoor PCB well inserted or not? Electrify the machine again and turn it on in the cooling operation...
18HEK03 Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1.
18HEK03 Outdoor unit Outdoor unit 1.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Forced fastening without careful centering Half union Flare nut...
Page 60
HSU-18HEK03 Removal Procedure Please embed the air filters into the unit along the grooves as installation. Please embed the hooks on air filter completely into the unit during installation. : http://splitoff.ru/tehn-doc.html...
HSU-18HEK03 Removal Procedure 11.2 Removal of Front Panel Open the front panel until it is on the horizontal position, and then release the pivots on both sides of the unit to remove the front panel. Please close the panels before start the removal procedure of front grille.
Page 62
Removal Procedure HSU-18HEK03 HOOKS three : http://splitoff.ru/tehn-doc.html...