E14 :Indoor fan motor malfunction
Notes:
When the unit is on ,don't pull out or insert the terminal of the motor (CN9), or else
The motor would be damaged.
whether terminal CN8
and CN9 on indoor PCB
well inserted or not?
Electrify the machine again and turn it on in the cooling
operation
Measure whether there is voltage 60VAC-230VAC
between the red wire and the black wire of Terminal CN9
on the indoor mainboard.
Check whether motor can run when turn on the unit
When fan motor is running Measure whether there is
voltage pulse 0-5VDC
the black side wire of Terminal CN8 on the indoor
the indoor mainboard is damaged and need replace
18HEK03
YES
YES
YES
between the middle wire and
YES
31
34
NO
Pull out and reinsert the terminals
NO
the indoor mainboard is damaged and need replace
NO
the indoor motor is damaged and need replace
NO
the motor of the indoor unit is damaged and need
replace