Omron NE1A Series Manual page 245

Safety network controllers
Hide thumbs Also See for NE1A Series:
Table of Contents

Advertisement

Monitoring Test Output Terminals: NE1A-SCPU01-V1
Explicit
Service
message
Monitor Mode for
Read
Terminal Mainte-
nance Information
Write
SV for Test Output
Read
Total ON Time or
Contact Operation
Counter
Write
Read Test Output
Read
Total ON Time or
Contact Operation
Counter
Reset Test Output
Reset
Total ON Time or
Contact Operation
Counter
Read Monitor
Read
Status of Test
Output Total ON
Time or Contact
Operation Counter
Read Test Output
Read
Safety Flag
Read Test Output
Read
Error Information
Cause
Read OR of Test
Read
Output Safety Flags
Read OR of
Read
Monitor Status of
Test Output Total
ON Times or
Contact Operation
Counters
246
Function
Service
Reads the monitor mode of
0E hex
maintenance information of the
test output (1 to 4) specified by
the Instance ID.
Writes the monitor mode of
10 hex
maintenance information of the
test output (1 to 4) specified by
the Instance ID.
Reads the SV of the total ON
0E hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the input (1 to 4) spec-
ified by the Instance ID.
Writes the SV of the total ON
10 hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the input (1 to 4)
specified by the Instance ID.
Reads the total ON time (unit:
0E hex
seconds) or contact operation
counter (unit: operations) for
the input (1 to 16) specified by
the Instance ID.
Resets to 0 the total ON time
05 hex
(unit: seconds) or contact
operation counter (unit: opera-
tions) for the test output (1 to 4)
specified by the Instance ID.
Reads the monitor status of the
0E hex
total ON time or contact opera-
tion counter of the test output (1
to 4) specified by the Instance
ID.
Reads the normal flag status
0E hex
for the test output (1 to 4)
specified by the Instance ID.
Reads the cause for the normal
0E hex
flag of the test output (1 to 4)
specified by the Instance ID
being OFF (error).
Reads the logical OR of the
0E hex
normal flag status for all test
outputs 1 to 4.
Reads the logical OR of the
0E hex
monitor status of the total ON
time or contact operation
counter for all test outputs 1 to
4.
Command
Class
In-
At-
code
stance
tribute
ID
ID
ID
307
01 to 04
83 hex
hex
hex
307
01 to 04
83 hex
hex
hex
307
01 to 04
86 hex
hex
hex
307
01 to 04
86 hex
hex
hex
307
01 to 04
84 hex
hex
hex
307
01 to 04
84 hex
hex
hex
307
01 to 04
85 hex
hex
hex
307
01 to 04
68 hex
hex
hex
307
01 to 04
76 hex
hex
hex
308
01 hex
69 hex
hex
308
01 hex
72 hex
hex
Appendix A
Response
Data size
---
1 byte
00 hex: Total ON time
mode
01 hex: Contact opera-
tion counter
mode
1 byte
---
00 hex: Total
ON time mode
01 hex: Contact
operation
counter mode
---
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to 4,294,967,295)
4 bytes
---
0000 0000 to
FFFF FFFF hex
(0 to
4,294,967,295)
---
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to 4,294,967,295)
---
---
---
1 byte
00 hex: In range
01 hex: Out of range
(over monitor
value)
---
1 byte
00 hex: Normal
01 hex: Error
---
1 byte
00 hex: No error
01 hex: Invalid
configuration
02 hex: Overcurrent
detection
05 hex: High constant
error
06 hex: Undercurrent
detection
---
1 byte
00 hex: All normal
01 hex: Error
---
1 byte
00 hex: All in range
01 hex: Test output out
of range (over
monitor value)