Download Print this page

Broan ULTRA GREEN XB110HL1 Installation Manual page 5

Single-speed ventilation fan with dimmable light and humidity sensor
Hide thumbs Also See for ULTRA GREEN XB110HL1:

Advertisement

Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
Fan
LIGHT WITH ON/OFF SWITCH
LIGHT
SWITCH
MANUAL
ON
SENSOR/
CONTROL
BLK
LINE
WHT
IN
GRD
SWITCH BOX
MANUAL
ON
SENSOR/
CONTROL
BLK
LINE
WHT
IN
GRD
SWITCH BOX
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
14/2
BLK
BLU
WHT
RED
BLK
ORG
WHT
BRN
GRD
14/3
LIGHT WITH DIMMER SWITCH
14/2
DIMMER
SWITCH
14/3
WHT
LIGHT
FAN
BLK
WHT
SENSOR
CONTROL
UNIT
BLK
BLU
LIGHT
WHT
RED
FAN
BLK
BLK
ORG
SENSOR
CONTROL
BRN
WHT
GRD
UNIT
XB110HL1 Installation Guide
3
4
Screw from
Parts Bag
• See OPERATION section on page
12 for details.
• SENSOR/CONTROL switch turns
humidity control on for automatic
WHT
operation and off for fan cleaning
and maintenance purposes.
• MANUAL-ON switch directly turns
fan on/off.
• MANUAL-ON switch is not required
to manually turn fan on (see page
10).
WHT
• SENSOR/CONTROL switch may
be located where it is not easily
accessed for everyday usage; it
may need to be labeled and located
where it can't be turned on without
being seen from fan to comply with
local and national codes.

Advertisement

loading