FIREPLACE BLOWER

The fireplace comes equipped with a heat activated blower. It is located
in the bottom of the fireplace, towards the front. It uses 120V and must
be connected to the main electrical circuit by a qualified electrician. For
connection, use the electrical box supplied with the unit located on the
bottom right corner of the fireplace.
If you wish to adjust the blower speed, the variable speed control (VRUW)
provided must be installed in line with the wiring. Again, use a qualified
electrician for installation.
If the blower requires servicing,
1. De-energize the power to the unit at its source.
2. Open the door (Figure 17A).
3. Remove both andirons from inside the firebox (Figure 17A).
4. Remove the bottom refractory panels (pieces 1 and 2, Figure 6). Remove
the 14 Cap screws with a 5/32 Allen Key.
5. Unplug the blower.
6. Disconnect the two terminals from the snap disc.
7. The blower is located at the front of the unit; magnets on the bottom
of the assembly are captured on tabs that extend down through the
bottom insulation shield.
8. Rotate the blower forward and remove it from underneath the firebox
(Figure 17B). Disconnect the insulated quick connects from the motor
terminals and attach to the new motor assembly. Re-install in reverse
order.
14
Drywall
2 x 3 Min.
Adjustable
Standoffs
A
Noncombustible Facing
Rock Board or Other
A
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Open Door
Figure 17A
Rotate the blower
forward to remove
B
Figure 17B
Remove Andirons
Blower