Installing the expansion unit in a rack

14
IBM® Netfinity® EXP300 Installation and User's Guide
The EXP300 expansion unit requires 3U (5.25 in) of Electronic Industries Association
(EIA) rack-mounting space.
Important: Review the documentation that comes with your rack enclosure for safety
and cabling considerations. When installing your expansion unit in a rack, take the
following precautions:
Install the expansion unit in a maximum 35 degree C environment.
To ensure proper air flow, do not block the air vents; usually 15 cm (6 inches) of
air space is sufficient.
Note:
Because of the limited space in some racks, it might be easier to connect
and route cables before you install the mounting brackets and hardware
devices.
To ensure stability, take precautions to prevent uneven loading of the rack.
Loading of the rack should begin at the bottom.
Turn off the power to your rack.
When multiple components are installed in a rack, take precautions to prevent
overloading of the power outlets.
The expansion unit should always be connected to a properly grounded outlet.
Refer to the rack documentation for instructions on removing the rack enclosure
doors and side panels.
Use the rack-mounting template and installation instructions that come with the
expansion unit to locate the rack-mounting holes and to install the unit in a rack
cabinet. If you do not have the template and instructions, you can use the following
steps to install your expansion unit:
1. Use the following illustration of the front and rear rack mounting flanges to
determine the appropriate rack-mounting holes for installing cage nuts or clip
nuts to secure the Netfinity EXP300 rails. From left to right, the illustration shows
the front and rear flanges respectively.
Front
Rear