INSTALLER'S GUIDE
NOTE: Do not allow insulation or other materials to accumu-
late inside pipe assembly when installing through hole.
DO NOT USE FIELD SUPPLIED COUPLINGS TO EXTEND
MAIN BODY PIPES (4" AND 2-1/2" PIPES). AIRFLOW RE-
STRICTION WILL OCCUR AND THE FURNACE OR BOILER
PRESSURE SWITCH MAY CAUSE INTERMITTENT OPERA-
TION.
5. InstallraincapandsmalldiameterpipeassemblyinWye
concentric fitting and large pipe assembly. Ensure small
diameterpipeisbottomedandcementedinWyeconcentric
fitting.
WARNING
s s
DRILL A PILOT HOLE IN THE VENT PIPE FOR THE SCREW
SIZE BEING USED. FAILURE TO DRILL ADEQUATE HOLES
MAY CAUSE CRACKING OF THE PVC COMPONENTS, AL-
LOWING FLUE GASES TO BE RECIRCULATED. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
6. SecureassemblytostructureasshowninFigure6usingfield
suppliedmetalstrappingorequivalentsupportmaterial.
NOTE: Ensure termination location clearance dimensions as
shown in Figure 5. Do not locate the vent cap directly to the
wall surface. A distance of 1" ± 1/2" is required to prevent
water accumulating between the vent fins.
NOTE: If assembly needs to be extended to allow side wall
thickness requirement, the two pipes supplied in the kit may
be replaced by using same diameter, field supplied SDR-26
PVC (D2241) pipe. Do not extend the 4" pipe (24" as shipped)
to more than 60 in. (See Figure 2). The 4" pipe may be short-
ened to 14" minimum.
IMPORTANT:
TheCommonwealthofMassachusettsrequirescompliance
withregulation248CMR4.00and5.00forinstallationof
through–the–wallventedgasappliancesasfollows:
Forallsidewallhorizontallyventedgasfueledequipment
installedineverydwelling,buildingorstructureusedin
wholeorinpartforresidentialpurposes,includingthose
ownedoroperatedbytheCommonwealthandwheretheside
wallexhaustventterminationislessthanseven(7)feetabove
finishedgradeintheareaoftheventing,includingbutnot
limitedtodecksandporches,thefollowingrequirementsshall
besatisfied:
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications.
For more information, please visit www.trane.com or www.americanstandardair.com
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are
committed to using environmentally conscious print practices.
18-CH83D1-1A-EN 01 Jul 2020
Supersedes 18-CH83D1-1 (December 2015)
CAUTION
1.INSTALLATIONOFCARBONMONOXIDE
DETECTORS.Atthetimeofinstallationofthesidewall
horizontalventedgasfueledequipment,theinstalling
plumberorgasfittershallobservethatahardwiredcarbon
monoxidedetectorwithanalarmandbatteryback-upis
installedonthefloorlevelwherethegasequipmentisto
beinstalled.Inaddition,theinstallingplumberorgasfitter
shallobservethatabatteryoperatedorhardwiredcarbon
monoxidedetectorwithanalarmisinstalledoneach
additionallevelofthedwelling,buildingorstructureserved
bythesidewallhorizontalventedgasfueledequipment.It
shallbetheresponsibilityofthepropertyownertosecurethe
servicesofqualifiedlicensedprofessionalsfortheinstallation
ofhardwiredcarbonmonoxidedetectors.
a.
Intheeventthatthesidewallhorizontallyvented
gasfueledequipmentisinstalledinacrawlspaceoran
attic,thehardwiredcarbonmonoxidedetectorwithalarm
andbatteryback-upmaybeinstalledonthenextadjacent
floorlevel.
b.
Intheeventthattherequirementsofthissubdivision
cannotbemetatthetimeofcompletionofinstallation,the
ownershallhaveaperiodofthirty(30)daystocomplywith
theaboverequirements;provided,however,thatduringsaid
thirty(30)dayperiod,abatteryoperatedcarbonmonoxide
detectorwithanalarmshallbeinstalled.
2.APPROVEDCARBONMONOXIDEDETECTORS.Each
carbonmonoxidedetectorasrequiredinaccordancewiththe
aboveprovisionsshallcomplywithNFPA720andbeANSI/UL
2034listedandIAScertified.
3.SIGNAGE.Ametalorplasticidentificationplateshall
bepermanentlymountedtotheexteriorofthebuildingata
minimumheightofeight(8)feetabovegradedirectlyinline
withtheexhaustventterminalforthehorizontallyvented
gasfueledheatingapplianceorequipment.Thesignshall
read,inprintsizenolessthanone-half(1/2)inchinsize,
"GASVENTDIRECTLYBELOW.KEEPCLEAROFALL
OBSTRUCTIONS".
4.INSPECTION.Thestateorlocalgasinspectorofthe
sidewallhorizontallyventedgasfueledequipmentshallnot
approvetheinstallationunless,uponinspection,theinspector
observescarbonmonoxidedetectorsandsignageinstalled
inaccordancewiththeprovisionsof248CMR5.08(2)(a)1
through4.
Thisappliancerequiresaspecialventingsystem.If
BAYAIR30CNVENTorBAYVENT200Bareused,acopyof
theinstallationinstructionsforthekitshallremainwiththe
applianceorequipmentatthecompletionofinstallation.The
ventingsysteminstallationinstructionscanbeobtainedfrom
themanufacturerbywritingtothefollowingaddress:
ResidentialSystems
6200TroupHighway
Tyler,TX75707
Attention:ManagerofFieldOperationsExcellence