Trane BAYAIR30CNVENT Installer's Manual page 3

Concentric vent kit for condensing furnaces and boilers

Advertisement

REMOVE RIBS
FROM CAP
COMBUSTION
AIR
ROOF BOOT
(FIELD SUPPLIED)
VENT
CONCENTRIC VENT
ROOF INSTALLATION
INSTALLATION -SIDE WALL VENT (SEE FIGURE 5)
1.­ Determine­the­best­location­for­the­vent­kit.
NOTE: Consider the following when determining the vent kit
location:
A. Vent kit positioned where the vent vapors will not damage
planting/ shrubs or air conditioning equipment or building
structure.
B. Vent kit positioned so it will not be affected by wind eddy
that may allow recirculation of combustion products, or air-
borne leaves, or light snow.
C. Vent kit positioned where it will not get damaged or be
subjected to foreign objects, such as stones, balls, etc.
D. Vent kit positioned where the vent vapors will not be ob-
jectionable.
2.­ Cut­1­hole­(5­in.­diameter)­­for­Vent­kit.
3.­ Partially­assemble­the­vent­kit.­Clean­the­pipe­ends­and­­
­
adjoining­sockets­with­PVC­primer­(ASTM­F-656)­and­­ ­
­
cement­using­PVC­cement­(ASTM­D-256).
­
a.­Cement­the­Wye­concentric­fitting­to­larger­diameter­kit­­­
­
­ pipe.­(See­Figure­1)
­
b.­Cement­the­rain­cap­to­smaller­diameter­kit­pipe.­(See­­
­
­ Figure­1)
4.­ Install­Wye­concentric­fitting­and­pipe­assembly­through­­
­
structure's­hole.
NOTE: Kit supplied stainless steel screw will be used to
secure the rain cap to the pipe.
7.­­­Cement­furnace­or­boiler­combustion­air­and­vent­pipes­to­
concentric­ vent­ assembly.­ See­ Figure­ 6­ for­ proper­ pipe­ at-
tachment.
8.­­­CHECKOUT:­Operate­the­furnace­or­boiler­to­make­sure­ALL­
pipe­joints­have­fastened­and­sealed­to­prevent­the­escape­of­
combustion­products­into­the­building.
NOTE: Two or more installations require a minimum separa-
tion distance of approximately one inch between vent kits.
18-CH83D1-1A-EN
MAINTAIN 12 IN.
VENT
(18 IN. FOR CANADA)
MINIMUM CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL. MAXIMUM OF
24 IN. ABOVE ROOF
SUPPORT
(FIELD SUPPLIED)
ELBOW
(FIELD SUPPLIED)
COMBUSTION
AIR
COMBUSTION
AIR
CONCENTRIC VENT
SIDE WALL
NOTE: To prevent the possiblility of condenate freeze-up, do
not install vent kits one above the other.
NOTE: FLUE GAS DEGRADATION
The moisture content of the flue gas may have a detrimental
effect on some building materials. This can be avoided by
using the roof or chimney venting option. When wall venting
is used on any surface that can be affected by this mois-
ture, it is recommended that a corrosion resistance shield
(24 inches square) be used behind the Vent Terminal. This
shield can be made of wood, plastic, sheet metal, etc. Also,
silicone caulk all cracks, seams, and joints within 3 feet of
the Vent Terminal.
(FIELD SUPPLIED)
VENT
ELBOW
COMBUSTION AIR
(FIELD
SUPPLIED)
CONCENTRIC VENT
SIDE WALL INSTALLATION
INSTALLER'S GUIDE
12" MIN TO
OVERHANG
"
1"
1
2
VENT
MAINTAIN 12 IN
MINIMUM CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL OR GRADE
WHICHEVER IS GREATER
COMBUSTION
AIR
STRAP
RAIN CAP
VENT
1" + 1/2"
Page 3