Download Print this page

Installer Final Check List; Leak Testing - Nexgrill 730-0896GH Instruction Manual

Outdoor gas grill

Advertisement

Available languages

Available languages

Minimum clearance from sides and back of
unit to combustible construction, 36 inches
(91cm) from sides and 36 inches (91cm) from
back
All internal packaging removed.
Knobs turn freely.
Burners are tight and sitting properly on
orifices.
GENERAL
Although all gas connections on the grill are leak tested
at the factory prior to shipment, a complete Gas leak
test must be performed at the installation site due to
possible mishandling in shipment, or excessive
pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks following
the procedures listed below. If the smell of gas is
detected at anytime you should immediately check the
entire system for leaks.
BEFORE TESTING
Make sure that all packing material is removed from
the grill including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER PERFORM LEAK TEST WITH AN OPEN
FLAME.
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings.
TO TEST
Make sure the control valves are in the "OFF"
1.
position and turn on the gas supply.
2.
Check all the connections and supply valve up
to and including the connection to the manifold
pipe assembly (the pipe that goes to the
burners). Soap bubbles will appear where a leak
is present.
3.
If a leak is present, immediately turn off the gas
supply and tighten the leaky fittings.
4.
Turn the gas back on and recheck.
5.
Should the gas continue to leak from any of the
fittings, turn off the gas supply and contact
customer service at U.S.A:1- 800-913-8999.

Installer Final Check List

Unit tested and free of leaks.
User informed of gas supply shut off valve
location
Only those parts recommended by the manufacturer
should be used on the grill.
Substitution will void the warranty. Do not use the grill
until all connections have been checked and do not
leak.
GAS FLOW CHECK
Each grill burner is tested and adjusted at the factory
prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners.
The flames of the burners should be visually checked.
Flames should be blue and stable with no yellow tips,
excessive noise or lifting. If any of these conditions
exist, check to see if the air shutter or burner ports are
blocked by dirt, debris, spider webs, etc. If you have
any questions regarding flame stability, please call
customer service U.S.A:1-800-913-8999.
Check all gas supply fittings for leaks before
each use. It is handy to keep a spray bottle of
soapy water near the shut-off valve of the gas
supply line. Spray all the fittings. Bubbles
indicate leaks.
6

Leak Testing

Advertisement

loading