4.7

Installation in a 19" mounting frame

The 19" mounting frame is for installation of 2 SCALANCE S devices in a 19" rack.
NOTICE
Approvals
Installation in a 19" mounting frame does not meet the requirements of the approvals:
ATEX, IECEx, FM, UL and UL Haz-Loc.
Operating temperature
Due to the horizontal installation, the maximum permitted operating temperature of the
SCALANCE S615 is reduced to 40° C.
Installation
1. Push the devices into the mounting frame.
2. Press the devices with slight pressure onto the back wall until the spring catch locks in place.
3. Screw the mounting frame in the 19" rack. For the precise dimensions, refer to the section
"Dimension drawings (Page 70)".
4. Connect the power supplies, refer to the section "Power supply (Page 51)".
5. Fit the connectors for the digital input and digital output, refer to the section "Digital
input/output (Page 53)".
SCALANCE S615
Operating Instructions, 10/2022, C79000-G8976-C389-07
Installation and removal
4.7 Installation in a 19" mounting frame
41