3-2. Outdoor fan control

¢ Outdoor fan motor
This outdoor unit has a DC fan motor. (Control method is different between AC and DC motors.)
¢ Fan speed
 Models: AOHG07KPCA and AOHG09KPCA
Fan speed is defined by outdoor temperature and rotation number of the compressor.
• Outside air temperature zone selection
Fan step
S-HIGH2
S-HIGH1
HIGH
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
rotation number of compressor.
Fan speed after defrost control: 930 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
Cooling
Heating
Y zone
930
950
930
950
930
690
950
690
780
690
780
690
780
690
780
690
780
550
680
510
610
480
580
480
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
Dry
Cooling or dry at low outdoor temp.
Y zone
Z zone
950
950
780
780
780
780
780
540
780
360
780
270
680
270
610
270
580
270
- (04-12) -
19°C
10°C
0°C
Unit: rpm
F zone
G zone
950
270
270
270
240
210
190
190
170
950
250
250
200
170
170
170
170
170