  • Page 1 DC inverter air conditioner MONOSplit with heat pump mode. User manual DSGNW 25/35 DSGT25-S/35-S...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY PRECAUTIONS................... 3 1.1. WARNINGS FOR USERS ................3 1.2. WEEE WARNINGS ................... 4 2. GENERAL CHARACTERISTICS ................5 3. DESCRIPTION OF SYSTEM COMPONENTS ............6 4. OPERATION ......................7 4.1. OPERATION USING SMARTPHONE/TABLET ..........7 4.2.
  • Page 3: Safety Precautions

    1. SAFETY PRECAUTIONS 1.1 WARNINGS FOR USERS The split air conditioner is only designed for climate control in indoor environments with surface areas and conditions of use appropriate for the installed capacity. Never use it for other purposes. The air conditioner is designed to be used by experts or trained persons in shops, industries or on farms, or by normal users for commercial use.
  • Page 4: Weee Warnings

    In cooling mode, the selected temperature should not be more than 5 °C lower than the outdoor temperature. This optimises both wellbeing and energy savings. In heating mode, select a temperature that is not too high. Do not direct the jet of air directly onto people. Avoid heating or cooling the air excessively.
  • Page 5: General Characteristics

    2. GENERAL CHARACTERISTICS  Air conditioner Dual Split with heat pump mode.  ULTRA DC inverter compressor for greater energy efficiency and more reliable and stable operation.  Microprocessor control.  R410A refrigerant gas.  Indoor units equipped with 5-speed fan: 3 speeds directly selectable plus “TURBO”...
  • Page 6: Description Of System Components

    3. DESCRIPTION OF SYSTEM COMPONENTS Air inlet INDOOR UNIT 1. Front panel 2. Air filter 3. Manual switch 4. Fins 5. Remote control 6. Refrigerant pipes Air outlet OUTDOOR UNIT 7. Drainage pipe 8. Shut-off valve 9. Protective grille Air inlet Air outlet...
  • Page 7: Operation

    4. OPERATION 4.1. OPERATION USING SMARTPHONE/TABLET The DSGNW25 and DSGNW35 air conditioners models are provided as standard with a WiFi module that, in combination with the App Air Connect, allows to control the air conditioners with Smartphone and Tablet. Air Connect consente di avere il pieno controllo della temperatura e del comfort di casa, in qualsiasi momento e da qualsiasi luogo vi troviate.
  • Page 8: Operation Using The Remote Control

    4.2. OPERATION USING THE REMOTE CONTROL IMPORTANT INFORMATION  Point the remote control at the air conditioner indoor unit receiver.  The remote control must be less than 8 metres away from the receiver.  There must be no obstacles between the remote control and the indoor unit receiver.
  • Page 9 DESCRIPTION OF THE BUTTONS REMOTE CONTROL FOR OUTDOOR UNIT Signal transmitter 1. ON/OFF BUTTON Press this button to turn the unit ON or OFF. It can also be used to deactivate the TIMER and/or switch on the night mode (SLEEP). 2.
  • Page 10 Press the COOL button to set the cooling operating mode. 5. “HEAT” button Press the HEAT button to set the heating operating mode. 6. “SWING” button (SWING and SWING  The “SWING ” button is only available on models that can swing to the left/right.
  • Page 11 2. “MODE” button By pressing this button, the operating mode will change as follows: 3. “SPEED” button Press this button to change the fan speed: 4. “TURBO” button  Pressing this button will turn the “TURBO” function on or off (the “TURBO” symbol will appear or disappear) in either cooling (COOL) mode or heating (HEAT) mode.
  • Page 12 Pressing the “TIMER” button again activates the off timer. 7. “HEALTH” button Pressing this button activates the “HEALTH” function. 8. “SLEEP” button When you press the “SLEEP” button, the night mode indicator on the indoor unit flashes.  When night mode (SLEEP) is activated, the cooling mode automatically increases the set temperature by 1 °C after 1 hour and another 1 °C after another hour.
  • Page 13  This function can be activated with the remote control when the unit is in cooling, dehumidification and automatic (cooling and dehumidification) mode.  The fins that guide the flow of air go back to their initial position in cooling mode. If the air conditioner is in heating mode, the indoor unit fan runs for three minutes at low speed before stopping.
  • Page 14 CHANGING THE BATTERIES Open the sliding cover in the direction of the arrow. Insert two new batteries (AAA), observing the polarity (+/-). Replace the cover. AUTOMATIC OPERATING MODE When the “ON/OFF” button is pressed, the air conditioner starts running. Press the “MODE” button and select automatic mode. Press the SPEED button to adjust the fan speed.
  • Page 15: Manual Operation

    4.3. MANUAL OPERATION If you cannot find the remote control or if it is not working, you can proceed as follows: MANUAL POWER-ON/OFF  If the unit is on, you can press the Auto button to turn the air conditioner off. ...
  • Page 16: Cleaning And Maintenance

    5. CLEANING AND MAINTENANCE 5.1. CLEANING AND MAINTENANCE OF THE INDOOR UNIT a) Turn off the air conditioner and unplug the power cable. b) Clean the outdoor unit using cloths that are dry or dampened with warm water.  N.B. Do not use water at a temperature of over 45 ℃...
  • Page 17: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING If a fault occurs, check the following points before requesting assistance. CONDITION PROBLEM  Has there been a power failure?  Are there any connection problems?  Is the electrical voltage below 90% or above 110% of the rated voltage? ...
  • Page 18  This is normal when there is a high temperature difference between the During cooling, white steam comes indoor unit and the air in the room out of the indoor unit During heating, white steam comes  This is normal when moisture is out of the indoor unit created during the defrosting process.
  • Page 19 2014/35/EU - Low Voltage Directive 2014/30/EU - Electromagnetic Compatibility Directive 2009/125/CE - ErP Directive 36061 Bassano del Grappa (VI) - ITALY Via Trozzetti, 20 Customer care: Tel. +39 0424-517800 – fax +39 0424-38089 www.baxi.it...