Download Print this page

Kenwood TS-440S Service Manual page 96

Hide thumbs Also See for TS-440S:

Advertisement

TS-440S
Item
2) AT - TU NE SW: OFF
Disconnect No. Q)
AT unit.
STBY: SEND
Set. SWR 1.25 reading when VFO
dial is turned.
3) STBY: REC
AT TU NE: ON
4) AF TU NE: OFF
Reconnect No. Q)
adjustment.
9 6
ADJ USTM ENT
Measurement
Condition
Test
equipment
Set as shown
connector from
right.
connector after
Adjustment
U n it
Part
U n it
Terminal
AT
VR2 Adjust VR2 until AT
TU NE indicator just
goes off.
S pecification/Remarks
M ethod

Advertisement

loading