Download Print this page

Kenwood TS-440S Service Manual page 93

Hide thumbs Also See for TS-440S:

Advertisement

• RX A D J U STM E N T
Item
Condition
1 . IF AMP
FREQ : 1 4. 1 750MHz
(common)
MODE : USB
RF GAIN Control : MAX
Use the minimum SSG input
possible during alignment.
2 . 2 n d M I X
FREQ : 1 4. 1 7 50M Hz
balance
MODE : USS
Connect the S S G t o A N T termina l .
3.
1 st M IX
FREQ : . 1 00.0 ( 1 00kHz)
balance
MODE : USS
4. IF TRAP
FREQ
: 29MHz Band
SSG : 45.05MHz
OUT
: 80 d Bµ
5.
RX D ET
1 ) FREQ :
1 4. 1 7 50 MHz
Balance
MODE : USB
RF G A I N : MIN
IF S H IFT : C ENTER
RF GAIN : MAX after
adjustment
6.
IF AMP
FREQ : 1 4. 1 7 50MHz
(SSB)
SSG : 1 4. 1 760 MHz
OUT : 0 dBµ
MODE : USS
7.
IF AMP
FREQ : 1 4. 1 750MHz
(FM)
SSG 1 4. 1 750 MHz
MOD : 1 kHz, DEV: 3kHz
OUTPUT : 30dBµ
MODE : FM
8.
S-METER
FREQ : 29.0000MHz
(FM)
MODE : FM
SSG : MOD OFF
OUTPUT : 30dBµ
9 .
S-METER
1 ) No signal
(SSS)
(SSG output: OFF)
2) FREQ :
1 4. 1 7 50 MHz
MODE : USB
SSG output :
3) SSG output : 40dbµ
1 0.
Squelch
1 ) MODE : CW
S ELECTIVITY : WIDE
threshold
SOL control : 1 2 o ' clock
1 ) FREQ : 1 4. 1 750 MHz
1 1 .
Noise
Blanker
NB SW : ON
SSG output : 1 4. 1 75MHz
First adjust 20dB input, then
use the minimum input as
possible.
2)
Noise Gen. : Low level
1 ) AF GAIN Control : 1 2 o ' clock
A
1 2. Beeper
Depressing
the same time
2) POWER SW : ON
3) Set to MEMORY CH 1 7 when
turning VFO.
ADJUSTMENT
Measurement
Test
e q u i pm e n t
U n it
SSG
Rear
AF V . M
Panel
Oscilloscope
AF dummy-
load (80)
SSG
AF V . M
Oscilloscope
RF V.M
IF
or
Oscilloscope
SSG
Rear
AF V . M
panel
Oscilloscope
S-meter
Rear
SSG
S-meter
panel
SdBµ
S peaker
SSG
Rear
DC V . M
panel
Oscilloscope
Noise Gen.
SP
AF V.M
and
key at
Oscilloscope
AF dummy
load
Adjustment
Term i n a l
U n it
Part
ANT
RF
T4, 5,3
MAX
EXT.SP
T7,8, 1 5 Repeat 2 - 3 times
9, 1 2,
i n case of T4, 5,3, 1 2,
1 0, 1 1
1 0, 1 1
RF
VR2
MAX AF Noise level.
VR 1
RF
MIN A F noise level .
RF
T1
Internal spurius beat
TC 1
M I N .
Q9
IF
TC 1
M I N
(emitter)
(R77)
IF
L 1 , 2,3
MAX AF output
4, 1 8, 5 Use the minimum
SSG input possible
during alignment.
IF
L6
MAX AF output
ANT
IF
VR3
Ful l scale
Set to starting point.
IF
VR2
(Meter zero)
ANT
IF
L3
S 1
Adjust counter clock-
wise from peak .
(turn s l u g out)
V R3
S 9
Adjust VR slowly and 1 2 o' clock
EXT.
IF
VR4
stop at threshold .
SP
RF
T26
MIN
ANT
R 1 46
27
EXT
SP
( 1 0k!J)
MIN noise level
T26
27
EXT.
IF
VRIO
1 20mV/80
SP
S pe c ificatio n/R ema rks
Method
S/N
1 0 dB or more at - 6dB
input. l V or more/80 at
AF GAIN control MAX .
Repeat 2 - 3 times 70dB or more
60
T'
40dB ± 6dB
± 1 0mV
TS-440S
30dB ± 1 0dB
9 3

Advertisement

loading