4-Wire Connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Cut out and remove part of metal ground strap, as shown.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack
toeasily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires
14
4. Use a Phillips screwdriver to connect the green ground wire
5. Use ³⁄
A
B
C
6. Connect line 2 (red) and line 1 (black) wires to the outer
7. Firmly tighten hex nuts.
8. Tighten strain relief screws.
9. Replace lower access cover.
B
D
from the power supply cord to the range with the ground-
link screw and ground-link section. The ground wire must be
attached over the ground-link section.
" (1.0 cm) nut driver to connect the neutral (white) wire
8
to the center terminal block post with one of the 10-32 hex
nuts.
A
B
C
A. 10–32 hex nut
B. Ground-link screw
C. Line 2 (red) wire
terminal block posts with 10-32 hex nuts.
NOTE: For power supply cord replacement, use only a
power cord rated at 250 volts minimum, 40- or 50-amps
that is marked for use with nominal 1³⁄
connection opening, with ring terminals and marked for use
with ranges.
IMPORTANT: Verify the tightness of the hex nuts.
F
E
D
D. Green ground wire
E. Neutral (white) wire
F. Line 1 (black) wire
" (3.5 cm) diameter
8