Motor Capacitor - Riello 484LD2X Installation, Use And Maintenance Instructions

Table of Contents

Advertisement

The control box can be used on burners with or
without a heater.
If the heater is damaged, insert the jumper 7)
WARNING
(Fig. 14) in the control box so that the burner can
work without the heater until the latter is replaced.
NOTE:
The control box is supplied with the jumper 7)(Fig. 14) al-
ready installed.
If the control box is installed on a burner with heater, it is neces-
sary to remove the jumper 7) before replacing the cover.
Connect the heater cables and thermostat as well.
S8792
Electrical system
7.1.2

Motor capacitor

The proper positioning of motor capacitor cover is shown in the
detail of Fig. 15.
To remove the motor capacitor cover from the burner, loosen the
screw 1).
7
Fig. 14
17
GB
D7497
1
Fig. 15
2903266