Technical Data
Temp. Setting
HIGH
MEDIUM
LOW
PROOF
Domestic: 850 Watts
International: 850 Watts
THERMAL CUT-OUT (TCO) INFORMATION (Auto Reset)
Open Temperature - 213.8°F ±37.4°F (101°C ± 3°C)
TEMPERATURE (
65°F (18.3°C)
68°F (20°C)
70°F (21.1°C)
75°F (23.9°C)
POWER BOARD IDENTIFICATION (Domestic vs. International)
Domestic (120VAC 50/60Hz) - Yellow Label
NOTE: For electronic control low voltage information, see Wiring Schematic in this manual.
#814750 - Revision A - January, 2011
TEMPERATURE INFORMATION
Preset Temp.
200°F
160°F
120°F
(Recommended 145°F - 159°F)
85°F
(Recommended 80°F - 100°F)
HEAT ELEMENT INFORMATION
THERMISTOR TESTING INFORMATION
± 10%)
Warming Drawer WWD30-2
Temp. Setting Range
80°F - 200°F
80°F - 200°F
80°F - 200°F
80°F - 110°F
Close Temperature - 158°F ± 40.1°F (70°C ± 4.5°C)
OHM READING (
International (240VAC 50/60Hz) - Green Label
6-2
Approximate Preheat Time
20 Minutes
15 Minutes
8 Minutes
0 - 5 Minutes
16.9 ± 10% Ohms
64.4 - 74.6 Ohms
± 10%)
14.8K
13.5K
12.9K
11.3K

Advertisement