Burner (To Be Revised) - Navien NCB-700-2S+/42K Service Manual

Condensing combi boiler
Table of Contents

Advertisement

4.7.9 Burner (to be revised)

Item
1. Pre-mixes air and gas to reduce emissions and increase efficiency.
Function
2. The burner produces the optimum air/gas mixture required to produce the correct level of heat during
1. Unable to initiate or sustain combustion.
Fault
2. Dust or soot deposits form on the burner's surface.
3. Gas leakage from the burner.
1. Abnormal combustion.
Symptoms
2. Unstable flame conditions and / or flame loss.
3. Ignition failure.
Error codes
E003, E004, E012
Visual inspection: Check for deposits forming on the burner surface and / or unstable flame conditions
Diagnostics
during operation.
combustion.
Fuel gas supply
Description
Burner Body
(Gas/air mixture and combustion zone)
Combustion air supply
System Details
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncb-700-3s/54k

Table of Contents