Proper installation

Suitable installation position
 Do not put any obstruction in front of the indoor unit, preventing proper ventilation and functioning.
 Do not install the unit in any of the following places:
 Where there is a danger of leaking flammable gases.
 Where there is substantial splashing of oil.
 Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated, or in a seaside resort
exposed to sea breezes. Contact your dealer.
 The air-conditioner and remote control must be at least 1 meter away from a TV set or radio.
 Drain the dehumidified liquid from the indoor unit into a spot that drains well.
Pay attention to operating noises
When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the
operating noise or vibration. If vibration is transmitted through the house, fix the unit with the aid of vibration-proof pads between the
unit and the fittings.
Select a place where cold or hot air, operation noises from the indoor and outdoor units do not cause any inconvenience to your
neighbours.
Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.
If you hear an irregular noise during operation, contact your dealer.
Inspection and maintenance
Depending on operating environment, the inside of the air-conditioner may become dirty after a few year operations. This will reduce
performance. In addition to normal cleaning, we would recommend inspection and maintenance. (This may lead the air-conditioner to
having a longer life without any trouble.)
Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).
We would recommend inspection and maintenance to be carried out during the off-season.
If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required.

Troubleshooting

Please carry out the following checks before making a service call.
The air-conditioner does not work at all.
 Has the power switch been turned off?
 Has the timer been set in the "ON" position?
 Is there a power failure or a blown fuse?
Poor cooling or heating
 Have you set the thermostat at a suitable temperature?
 Is the air filter clean? (Not clogged?)
 Have you left any doors or windows open?
 Is there any direct sunlight entering the room?
 Is there a heat source in the room?
 Are there too many people in the room?

Notice

Airflow
Air is not blown out when starting the HEATING operation.
(1.5 seconds ON, 0.5 seconds OFF)
Air is not blown out for 5 to 15 minutes or cool air is
blown out for a moment at HEATING operation.
(1.5 seconds ON, 0.5 seconds OFF)
Air is not blown out when starting the DRY operation.
Airflow has stopped to prevent blowing out of cold air until the
indoor heat exchanger has warmed up. (2 to 5 minutes)
RUN light blinks slowly
When outdoor temperature is low and humidity is high, the
unit sometimes performs defrosting automatically. Please
wait. During defrosting, water or steam may release from the
RUN light blinks slowly
outdoor unit.
The indoor fan may stop to prevent re-evaporation of
dehumidified moisture and to save energy.
(RUN light is on)
EN-31
If the air-conditioner does not
operate properly after you have
checked the left points, or if any
doubt still exists after you have
consulted below page and page
32, or if things happen as shown
on page 33, switch off the power
and contact your dealer.