Motronic injection and ignition system (6-cylinder) - Edition 02.1999
Electrical test of solenoid valve 1 for activated charcoal filter -N80
-
Unplug connector from ACF valve -N80.
-
-> Measure resistance between contacts on valve using hand-held multimeter V.A.G 1526.
Specification: 22...30 ω
If the specification is not attained:
-
Renew solenoid valve for activated charcoal filter system -N80.
If the specification is attained:
-
Test voltage supply => Page
Testing power supply to solenoid valve
Note:
The ACF valve receives its power supply via the fuel pump relay.
-
Test fuse for ACF valve
=> Current flow diagrams, Electrical fault finding and Fitting locations binder
If the fuse is OK:
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
-
Unplug connector on ACF valve -N80.
-
-> Connect diode test lamp V.A.G 1527 between engine earth and socket 1 on the connector.
-
Operate starter.
The diode test lamp should light up.
If diode test lamp does not light up:
73
.
5.2 - Testing solenoid valve 1 for activated charcoal filter -N80
Audi A8 1994 ➤