Si011088
3. Removal of Thermistor ASSY
Procedure
Step
1
Cut the clamp.
2
Release the outdoor
temperature thermistor
ASSY.
3
Remove the cover.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
(R13454)
Outdoor temperature
thermistor ASSY
(R13455)
Cover
(R13456)
Removal of Thermistor ASSY
Points
9