6. Reactor / Partition Plate

Warning
Step
1
Remove the 2 screws
of the reactor.
2
Slide the reactor
upward to unfasten the
2 hooks.
3
Remove the reactor.
4
Remove the 2 screws,
and then the partition
plate.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Reactor
Partition plate
(R22411)
Hook
(R22412)
When reassembling, fit the
hole on the partition plate to
the hook on the bottom
frame.
(R22413)
Reactor / Partition Plate
Points
Hook
(R22414)