8. Attach sections together via the bolts pictured in the
illustration below.
9. Apply bead of butyl to top of bulk heads and slip on
stainless steel bulkhead cap. Also apply silicone to
seam between joints.
10. Use finger to smooth silicone as thin as possible at
masking tape on inside and outside of rear mullion
(apply additional silicone if necessary). Remove
tape applied on line #4.
11. Remove front, back and end shipping braces.

SERIAL PLATE LOCATION

The serial plate is located on the left side of
the Panel Lower Base Rmt as shown below.
FRONT CASE BOLT
(USE 3/8"-16 x 1 1/2"
BOLT IN HOLE)
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 •
Q3-SS Refrigerated Wedges and Standard Cases Line up
taper pins and line-up plates with holes on adjoining case.
Bolting is located at the rear of the case, behind the air
discharge wall, and behind the front body panel. The cases
are bolted together in front by means of a bracket located
behind the front panel. Remove the front panel by
unscrewing these bottom screws.
LINE-UP PIN
(INSERT INTO
UPPER 1/2" HOLE)
CASE BOLTING
(USE 3/8"-16 x 1 1/2"
BOLT IN LOWER HOLE)
CASE BOLTING
(USE 3/8" - 16 x 1
1/2" BOLT IN HOLE)
LINE-UP PLATE
(INSERT INTO
VERTICAL SLOT)