Section 2
Names and Functions of Components
Reader/Writer Controls
 RESET
You can restart the Reader/Writer.
You can restart the Reader/Writer by using a RESET command or by performing a reset with the DCP
protocol from a Web browser. The Reader/Writer will return the execution results and reset itself.
Host device
Host device
Reader/Writer operation
If you reset the Reader/Writer during cyclic data exchanges, the connection will be broken and must be re-established
from the IO controller.
If the Reader/Writer is reset with the DCP protocol, it will be restored to the default settings.
All of the network settings will be restored to zeros, including the IP address, subnetwork, and default gateway. Use the
IP address settings with the DCP protocol to reset the IP address as required.
RFID System
38
User's Manual
(PROFINET)
Reader/Writer
Reset
Reader/Writer
Response
Self-reset processing
Initialization Waiting for connection