Specifications - Lenovo ThinkCentre A35 8139 User Manual

Lenovo thinkcentre a35 8139: user guide
Table of Contents

Advertisement

Specifications

This section lists the physical specifications for your computer.
Dimensions
Height: 374 mm (14.72 in.)
Width: 180 mm (7.09 in.)
Depth: 458 mm (18.03 in.)
Weight
Minimum configuration as shipped: 9.1 kg 20.06 lb)
Maximum configuration: 10.2 kg (22.5 lb)
Environment
Air temperature:
System on: 10° to 35°C (50° to 95° F)
System off: 10° to 43°C (50° to 110° F)
Maximum altitude: 3000 m (10000 ft)
Note: The maximum altitude, 3000 m (10000 ft),
is the maximum altitude at which the specified air
temperatures apply. At higher altitudes, the
maximum air temperatures are lower than those
specified.
Humidity:
System on: 10% to 90%
System off: 10% to 90%
Electrical input
Input voltage:
Low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input frequency range: 50–60 Hz
Voltage switch setting: 115 V ac
High range:
Minimum: 200 V ac
Maximum: 240 V ac
Input frequency range: 50–60 Hz
Voltage switch setting: 230 V ac
Input kilovolt-amperes (kVA) (approximate):
Minimum configuration as shipped: 0.158 kVA
Maximum configuration: 0.213 kVA
Note: Power consumption and heat output vary
depending on the number and type of optional
features installed and the power-management
optional features in use.
4
User Guide
Heat output (approximate) in British thermal units (Btu)
per hour:
Minimum configuration: 95.6 Btu/hr (28 watts)
Maximum configuration: 129.7 Btu/hr (38 watts)
Airflow
Approximately 2.45 cubic meters every minute (66
cubic feet every minute) maximum
Acoustical noise-emission values
Average sound-pressure levels:
At operator position:
Idle: 32 dBA
Operating: 42 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 28 dBA
Operating: 36 dBA
Declared (upper limit) sound-power levels:
Idle: 4.2 bels
Operating: 4.7 bels
Note: These levels were measured in controlled
acoustical environments according to the procedures
specified by the American National Standards Institute
(ANSI) S12.10 and ISO 7779 and are reported in
accordance with ISO 9296. Actual sound-pressure levels
in a given location might exceed the average values
stated because of room reflections and other nearby noise
sources. The declared sound-power levels indicate an
upper limit, below which a large number of computers
will operate.

Advertisement