Summary of Contents for La Crosse Technology WS-7049-Mah

  • Page 1 WS-7049U Wireless 433 MHz Weather Station with Forecast Instruction Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Topic Inventory of Contents/Additional Equipment Quick Set-Up Guide Detailed Set-Up Guide Battery Installation Program Mode Function Keys Time Setting Features Weather Forecast Indoor Temperature and Humidity Outdoor Temperatures Minimum & Maximum Records (Indoor, Outdoor & Resetting) Additional Remote Temperature Sensor Units (Set-Up, Viewing &...
  • Page 3: Inventory Of Contents/Additional Equipment

    Indoor LCD Forecast LCD Outdoor LCD Figure 1 ADDITIONAL EQUIPMENT (not included) 1. Two, fresh AA 1.5V batteries for indoor weather station. 2. Two, fresh AA 1.5V batteries for remote temperature sensor. 3. One Philips screwdriver for mounting. Figure 2 Mounting...
  • Page 4: Quick Set-Up Guide

    NOTE: Fog and mist will not harm your remote temperature sensor but direct rain must be avoided. To complete the set up of your indoor weather station after the 10 minutes have passed please follow the steps on pages 8 and 9.
  • Page 5: Detailed Set-Up Guide

    4. Replace the battery cover by sliding upwards. Be sure battery cover is on securely. B. Indoor Weather Station 1. Remove the battery cover. To do this, insert a solid object in the space provided at the lower-central position of the battery cover, then push up and pull out on the battery cover.
  • Page 6: Program Mode

    Program Mode Programming Note: If 30 seconds are allowed to pass or either the IN or the OUT button is pressed during programming modes, the unit will set the last information entered—the display will stop flashing and return to normal time-date readings A.
  • Page 7: Weather Forecast

    FEATURES OF THE WS-7049U Time Display Indoor Temperature Weather Tendency Arrow I. Weather Forecast The weather forecasting feature is estimated to be 75% accurate for the next 12 to 24 hours. The weather forecast is based solely upon the change of air pressure over time.
  • Page 8 A. Weather Icons There are 3 possible weather icons that will be displayed in the FORECAST LCD: Sunny—indicates that the weather is expected to improve (not that the weather will be sunny). Sun with Clouds—indicates that the weather is expected to be fair (not that the weather will be sunny with clouds).
  • Page 9: Indoor Temperature And Humidity

    II. Indoor Temperature and Humidity The current indoor relative humidity (viewed below the time) and temperature (viewed below the relative humidity) are displayed in the INDOOR LCD. III. Outdoor Temperature The outdoor temperature is viewed in the OUTDOOR LCD. When there is more than one remote temperature sensor unit in operation, a arrow will appear above the CH 1 2 3 area at the bottom of the LCD.
  • Page 10: Units (Set-Up, Viewing & Operation)

    Then insert batteries into all the remote temperature sensor units in numeric sequence. Second, install batteries into the indoor weather station. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 minutes.
  • Page 11 B. Viewing and Operating Multiple Remote Sensors To view the temperature of a different remote sensor unit, press and release the “CH” button. An arrow over one of the numbers at the bottom of the LCD will be seen. To view the minimum/maximum temperature: 1.
  • Page 12: Mounting

    Also, extreme and sudden changes in temperature will decrease the accuracy of the indoor weather station and changes in elevation will result with inaccurate weather forecasting for the next 12 to 24 hours. These changes will require a 12 to 24 hour wait before obtaining reliable data.
  • Page 13 B. MOUNTING WITH ADHESIVE TAPE 1. With a nonabrasive solution, clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold. The mounting surface should be smooth and flat. 2. Remove the protective strip from one side of the tape.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Problem: The LCD is faint Solution: Replace batteries Problem: No outdoor temperature is displayed. Solution: 1. Remove all batteries, reinsert into remote temperature sensor first, then into the indoor temperature station. 2. Place remote temperature sensor closer to the indoor temperature station.
  • Page 15: Maintenance & Care

    MAINTENANCE AND CARE INSTRUCTIONS • Extreme temperatures, vibration and shock should be avoided to prevent damage to the units. • Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents. They may mark the displays and casings. •...
  • Page 16: Specifications

    Indoor humidity checking interval Outdoor temperature checking interval (Remote Temperature Sensor) Outdoor temperature reception (Indoor Weather Station) Transmission Range: Power Supply: Indoor Weather Station: Remote Temperature Sensor: Battery life cycle: Recommended battery type: Dimensions (L x W x H)
  • Page 17: Warranty Information

    Before sending the indoor weather station in for repairs, contact La Crosse Technology. The indoor weather station will be repaired or replaced with the same or similar model. This warranty does not cover any defects resulting from improper use, unauthorized repairs, faulty batteries, or the indoor weather stations inability to receive a signal due to any source of interference.
  • Page 18 For warranty work, technical support or information contact: FCC ID: OMO-01RX (Receiver), OMO-01TX (transmitter) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.