Si061063
Step
Release the 2 hooks
10
and remove the
indication lamp cover.
Release the 4 hooks
11
and remove the display
PCB.
Disconnect the
12
connectors [S24], [S29]
from the display PCB.
Feature of the display
13
PCB
Removal Procedure
Removal of Touch Sensor PCB / Signal Receiver PCB / Display PCB
Procedure
Hook
Indication lamp
cover
Hook
[S24]
[S29]
Points
Display
PCB
(R13342)
Display
PCB
(R13343)
[S24] [S29] : control PCB
(R11561)
(R11562)