same position. We recommend that you set them to the 0dB (full) position.
Connect the speaker as shown. Always use Channel A's output connector.
RKPKR= _êáÇÖÉ=ãçåç=ãçÇÉ=ÑÉ~íìêÉë=
Bridged mono mode combines the power of both channels into one speaker. This results in twice the
voltage swing, four times the peak power and just less than three times the full power of a single
channel.
ohms part of the load, and the other channel shares the other 4 ohms part. The power into 4 ohms from
an fP 2600 (MLS at 0dB) is 840W. So, the total bridged power into the 8 ohms load will be 2 x 840 =
1680W
RKQ= fãéÉÇ~åÅÉ=ã~íÅÜáåÖ=Ejip=ëïáíÅÜF=
TM
The MLS
switch is located on the rear panel. The MLS (Minimum Load Select) switch offer
impedance matching, so you can drive the fP 2600 into 2 ohms without increased heat loss.
As stated earlier, the fP 2600 can produce 850 watts into both, 2 and 4 ohms. Use lower MLS
(-3dB) when connecting to lower impedance loads as shown in table 1. As can be seen in table 1, the fP
2600 can produce output power in excess of 850 watts.
fP 2600
LOAD CONFIGURATION
16 ohms Stereo (2 channel)
8 ohms Stereo (2 channel)
4 ohms Stereo (2 channel)
2 ohms Stereo (2 channel)
16 ohms Mono Bridged
8 ohms Mono Bridged
4 ohms Mono Bridged
* Not recommended
(thermal protection may occur at high continuous power)
Power in watts (EIA 1 kHz, 1% THD)
Table 1.
i~ÄKÖêìééÉå==
=
rëÉê=j~åì~ä===Ñm=OSMM======sÉêëáçå=MKV========OMMPJNMJMT=
=
=
One way to understand the load
and power from the amplifier's
perspective in bridged mode is
that it is zero voltage at the
centre of the voice-coil
winding. This is because the
coil is driven with positive
voltage at one pole and an
equivalent negative voltage at
the other pole. So, if an 8 ohms
load is connected in bridged
mode, one channel shares one 4
MLS SWITCH SETTING
-3 dB
110 W
240 W
430 W
870 W
480 W
870 W
1740 W
=
======================
TM
setting
0 dB
215 W
430 W
840 W
1540 W *
840 W
1680 W
3000 W *
U
========================