The chart below shows the heat power produced in watts, in kcal per hour, and also in BTU per hour.
fP 2600
8 ohms
4 ohms
2 ohms
note 1
Average power with music as program source. The amplifier driven to clip level.
note 2
Normal music power with 9dB headroom, IEC standard power rating.
The efficiency can also be calculated, it being the output-power divided by the input-power:
560 watts / 1330 watts= 42%.
T= `lkkb`qflkp=
TKN= fåéìí=ÅçååÉÅíáçåë=
TKNKN= _~ä~åÅÉÇ=áåéìíë=
The XLR input connectors are electronically balanced, and wired according to the IEC 268 (pin 2 =
"hot"), and wired in the following way:
PIN 1
GROUND/SHIELD
PIN 2
HOT (+)
PIN 3
COLD (-)
Figure 4: XLR input connector
Within the Neutrik® Combojack there is a ¼"(6.3mm) phone jack wired in parallel with the XLR.
TIP
HOT
RING
COLD
SLEEVE
GROUND/SHIELD
i~ÄKÖêìééÉå==
=
rëÉê=j~åì~ä===Ñm=OSMM======sÉêëáçå=MKV========OMMPJNMJMT=
HEAT POWER
1/3 Power(1)1/8 Power (2) 1/3 Power(1) 1/8 Power (2)1/3 Power(1)1/8 Power (2)
[W]
[W]
443
373
770
630
1400
1100
The input impedance is high enough (20 kohms balanced) to
allow "daisy-chaining", or multiple parallel input
connections. The headroom of the input circuits is also great
enough to accept the maximum output level from virtually
any low-level signal source. Balanced signals are less
sensitive to AC hum and radio interference. The source
impedance should be less than 1 kohms to avoid high
frequency loss in long cables.
=
=
kcal / h
kcal / h
380
320
660
540
1200
950
Figure 5: XLR balanced
Figure 6: ¼" TRS plug
=
======================
BTU / h
BTU / h
1510
1270
2630
2150
4780
3750