Conducted Noise; Voltage Tolerance - Seagate IRONWOLF ST10000VN0004 Product Manual

Standard 512e model
Hide thumbs Also See for IRONWOLF ST10000VN0004:
Table of Contents

Advertisement

2.5.1.1
Typical current profiles
Figure 1.
Typical 5V and 12V startup and operation current profiles (10TB)
2.5.2

Conducted noise

Input noise ripple is measured at the host system power supply across an equivalent 80-ohm resistive load on the +12 V line or an
equivalent 15-ohm resistive load on the +5V line.
• Using 12V power, the drive is expected to operate with a maximum of 120mV peak-to-peak square-wave injected noise at up to
10MHz.
• Using 5V power, the drive is expected to operate with a maximum of 100mV peak-to-peak square-wave injected noise at up to
10MHz.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write current.
Note
2.5.3

Voltage tolerance

Voltage tolerance (including noise):
5V ±5%
12V ± 10%