Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with these instructions will result in voiding of the product warranty and may result in personal injury
and/or property damage.
Number
Description
1
Flooring Systems
2
Wood Truss
3
Air Ducts
4
CRD-1WT or CRD-2WT assembly
5
Mounting Angle
6
Resilient Channel
7
Gypsum Board
8
Grille (not supplied)
Finishing System
9
(not shown)
These instructions describe the installation of a
CRD-1WT or CRD-2WT in designs: L528, L546, L558,
L562, L574, L576, L581, L583, L585, L592, M501, M503,
M508, P533, P538, P545, P547, P548, P554, and P580
as detailed in the UL Fire Resistance Directory.
Receiving and Handling
Upon receiving dampers, check for both obvious
and hidden damage. If damage is found, record all
necessary information on the bill of lading and file
a claim with the final carrier. Check to be sure that
all parts of the shipment, including accessories, are
accounted for.
Dampers must be kept dry and clean. Indoor storage
and protection from dirt, dust and the weather is
highly recommended. Do not store at temperatures in
excess of 100°F (38°C).
Safety Warning
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury
or death. Read the installation, operating, and
maintenance instructions thoroughly before installing
or servicing this equipment.
1
2
5
7
CRD-1WT and CRD-2WT
3
Table of Contents
General Information . . . . . . . . . . . . . . . . . . 2
Pre-Installation Guidelines
Installation - Hanger Method . . . . . . . . . . . . . 3
Installation - Base Mount Method . . . . . . . . . . . 5
Field Installation of Steel Plenums for CRD-1WT . . . 6
Fabrication of Fiberglass Ductboard Plenum for
CRD-1WT . . . . . . . . . . . . . . . . . . . . . . . 7
Document 474094
4
6
8
. . . . . . . . . . . . . . 3
CRD-1WT & CRD-2WT
1

Advertisement

loading

Summary of Contents for Greenheck CRD-1WT

  • Page 1 Fabrication of Fiberglass Ductboard Plenum for Receiving and Handling CRD-1WT ..... . . 7 Upon receiving dampers, check for both obvious and hidden damage.
  • Page 2: General Information

    5) Ceiling penetrations shall be located between floor/ceiling trusses. 6) The CRD-1WT’s supplied without a factory supplied plenum box require a steel or ductboard plenum to be field installed (see pages 4 - 6). The CRD-2WT’s are always provided with a factory supplied plenum box.
  • Page 3: Installation

    Hanger Method The hanger method is the standard mounting method for CRD-1WT’s. It may also be used in lieu of the base mount method (see below) with the CRD-2WT. However, the hanging wire or straps would have to be field supplied.
  • Page 4 Base Mount Method The base mount method is the standard mounting method for CRD-2WT’s. It may also be used on CRD-1WT’s with steel plenums that either have an insulation band or are duct mounted. An insulation band is used on units with steel plenums that have a width or height greater than 12 inches [305 mm](see Figure 7A or 7B for reference).
  • Page 5 3. Plaster Flange 4. Gypsum Board 5. Grille 6. RC Channel 7. Steel Plenum Figure 7A: Grille Mount of CRD-1WT with Steel Plenum CRD-1WT Grille Mount, Steel Plenum Figure 7B: Grille Mount of CRD-2WT 1. Damper 2. Mounting Angle 3. Plaster Flange 4.
  • Page 6 6) Plenum shall be attached to ceiling damper subframe using UL 181 listed tape (Figure 12). 7) Refer to Figure 4-7 for ceiling damper installation. The CRD-1WT ceiling is classified for use in specific wood truss ceiling assemblies. See UL Fire Resistance Directory for floor/ceiling and roof/ceiling design numbers listed on page 1.
  • Page 7 1 Piece Duct 2 Piece “U” Duct 2 Piece “L” Duct 4 Piece Duct Plenum Top Figure 11: Assembly of ductboard plenum 15 in. maximum Plaster Flange Damper Frame Damper with Field Installed Duct Board Plenum Assembly Figure 12 CRD-1WT & CRD-2WT...
  • Page 8: Our Commitment

    As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website at Greenheck.com/Resources/Library/Literature.