Number
Description
1
Flooring Systems
2
Wood Truss
3
Air Ducts
4
CRD-300WT assembly
5
Mounting Angle
6
Gypsum Board
7
Grille
Finishing System
8
(not shown)
10.375
Figure 2: Isometric view of a
CRD-300WT damper with plaster flange.
This manual is the property of the owner and is required
for future maintenance.
Please leave it with the owner when the jobs is complete.
1
2
5
Figure 1: Isometric
view of CRD-300WT in
wood truss system.
6
3.625
10.375
CRD-300WT Installation
3
Equipment Needed:
Fan/CRD Parts
(1) SP-AP Fan
(1) SP-AP Installation Bracket
(1) Ceiling Radiation Damper (CRD-300WT)
(1) Plaster Flange
(1) Sleeve
Parts Kit:
(1) Wire retaining bracket
(5) Self-tapping, Philips head, 1.25in screws
(taped to backdraft damper of fan)
(4) Machine screw, hex head, #10-32 x 0.5in
(4) Lock Nuts, #10-32
(4) Self-tapping, hex head, 0.5in screws
(1) Self-tapping, hex head, 0.5in screw
(for wire retaining bracket)
(4) Tinnermann U-Clips
(1) CRD-300WT IOM
485180 SP-AP0511W/L & CRD Installation
Document 485180
for SP-AP0511W/L
4
7
1

Advertisement

loading

Summary of Contents for Greenheck CRD-300WT

  • Page 1 Figure 1: Isometric (not shown) view of CRD-300WT in wood truss system. Equipment Needed: Fan/CRD Parts (1) SP-AP Fan (1) SP-AP Installation Bracket (1) Ceiling Radiation Damper (CRD-300WT) (1) Plaster Flange 3.625 (1) Sleeve Parts Kit: (1) Wire retaining bracket 10.375 10.375 (5) Self-tapping, Philips head, 1.25in screws...
  • Page 2 SP Fan Size authority having jurisdiction. Width Height 1 Hour Com- (in.) (in.) The CRD-300WT series dampers are classified to bustible function as a heat barrier in air handling penetrations SP-AP0511W through fire resistive membrane ceilings. They are CRD-300WT ⁄...
  • Page 3 13. Secure the plaster flange onto the fan/CRD 3. Position the CRD-300WT on the SP-AP Fan assembly by fastening the (4) self-tapping screws Assembly so that the wire chase on the CRD is provided into the Tinnerman clips installed in step 2.
  • Page 4 As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website at Greenheck.com/Resources/Library/Literature.