Download Print this page

Advertisement

Quick Links

ECPK91
Extractors
Installation, use and maintenance
www.cda.eu
Cod:0103091010-00.02

Advertisement

loading

Summary of Contents for CDA ECPK91

  • Page 1 ECPK91 Extractors Installation, use and maintenance www.cda.eu Cod:0103091010-00.02...
  • Page 2: Table Of Contents

    Contents Important information Important notes Using your extractor Care and maintenance Changing the charcoal filter Mounting your extractor Ducting Installation Mains electricity connection Electrical information Troubleshooting...
  • Page 3: Important Information

    Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance Model...
  • Page 4 At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services. Disposing of a household appliance separately avoids possible negative consequences for the environment and health. It also enables the constituent materials to be recovered, saving both energy and resources.
  • Page 5 Information and Advice CAUTION:Accessible parts may become hot when used with cooking appliances. In certain circumstances electrical appliance may be a danger hazard. A) There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels.
  • Page 6 Information and Advice L)the range hood is inteded to be installed over a hob having no more than four hob elements. M) Indoor use and household use only. N)When the appliance is not in use and before cleaning, unplug the appli- ance from the outlet.
  • Page 7: Using Your Extractor

    Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Fig. 1 Control Panel B - Speed level buttons C - Light button •...
  • Page 9: Changing The Charcoal Filter

    Cleaning the grease filter The grease filters should be kept clean to minimise the risk of fire. At least once a month you should remove and clean the grease filters with hot soapy water. You can also wash the grease filters in a dishwasher, ensuring that you place it in an upright position to prevent damage from other items in the dishwasher.
  • Page 10: Mounting Your Extractor

    Changing the light This appliance is fitted with energy saving LED lighting that has a considerably longer life expectancy than traditional filament bulbs. These are not user-replaceable in the unlikely event of a failure. Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights.
  • Page 11 The width of any hob must not be greater than the width of the extractor installed above it. Ducting and ventilation For best performance and lowest noise output, we recommend the use of 150mm ducting. You can also use 120mm ducting but this will reduce performance.
  • Page 12: Installation

    Installation ceiling Note • We recommend that you seek the Extractor height help of another individual when installing this product. Always wear adequate PPE (Personal Protective Equipment). B - clearance required • The fixings supplied are suitable Gas: 650mm recommended. for most installations.
  • Page 13 the chimney section, use the calculation shown on this page for your extractor (also refer to fig 4): A = Height of gas hob burner or electric hotplate height from the kitchen floor B = Clearance required: Gas hobs 650mm recommended 1 –...
  • Page 14 be at least the minimum height specified). 5. Place the chimney section over the body assembly, as shown in fig 6. With the help of another individual, raise the whole assembly to the ceiling and fix securely in place using four screws appropriate for the wall plugs inserted in step 2.
  • Page 15: Mains Electricity Connection

    Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is DOUBLE POLE SWITCHED FUSED SPUR OUTLET connected by a qualified electrician, who is a member of the N.I.C.E.I.C.
  • Page 17 Measured power consumption in standby mode Sound power level 61.0 69.7 (D) Hood c i f 91 (A) Hood E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
  • Page 18 01949 862 012 or email customer.care@cda.eu For more information please contact: The Sales Department on 01949 862 010 or email sales@cda.eu Customer Care Department. The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY 01949 862 012 01949 862 003 customer.care@cda.eu www.cda.eu...

This manual is also suitable for:

Ecpk91ss