Download Print this page
Omega HE-XT103 User Manual

Omega HE-XT103 User Manual

Advertisement

Quick Links

User' s Guide
MADE IN
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
HE-XT103
HE-XT104
12 Digital DC Inputs,
24 Digital DC Inputs,
12 Digital Outputs,
16 Digital Outputs,
2 Analog Inputs
2 Analog Inputs
(Medium Resolution)
(Medium Resolution)

Advertisement

loading

Summary of Contents for Omega HE-XT103

  • Page 1 User’ s Guide MADE IN Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info HE-XT103 HE-XT104 12 Digital DC Inputs, 24 Digital DC Inputs, 12 Digital Outputs, 16 Digital Outputs, 2 Analog Inputs 2 Analog Inputs (Medium Resolution)
  • Page 2 Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3 Panel Cut-Out and Dimensions Specifications Note: Max. panel thickness: 5 mm. Specifications Digital DC Digital DC Inputs XLT103 XLT104 XLT103 XLT104 Outputs 12 including 16 including 24 including 12 including 4 Outputs per Inputs per Module configurable configurable configurable configurable Module HSC inputs HSC inputs...
  • Page 4 External DIP Switch Settings (or Jumpers Settings) Section 3 continued As seen when looking at the top of the XLt unit: Memory Slot: The External DIP Switches are used for termination of Uses Removable Memory for data logging, screen the RS-485 ports. The XLt is shipped un-terminated. DIPSW3: FACTORY USE captures, program loading and recipes.
  • Page 5 Filter Filter Constant sets the level of digital filtering according to the following chart. Filter Constant Scans Digital Filtering. The illustration above demonstrates the effect of digital filtering (set with Filter Constant) on module response to a temperature change. I/O Register Map MJ2 Pinouts in Full and Half Duplex Modes Registers Description...
  • Page 6 Safety When found on the product, the following symbols specify: Warning: Electrical Warning: Consult Shock Hazard. user documentation. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous locations only WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2 AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1, DIVISION 2 WARNING –...
  • Page 7 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 8 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors...

This manual is also suitable for:

He-xt104