10. Installation
Setting an indoor unit installation option (suitable for the condition of each installation location)
1 Check whether power is supplied or not.
– When the indoor unit is not plugged in, there should be additional power supply in the indoor unit.
2 Set the installation option according to the installation condition of an air conditioner.
– The default setting of an indoor unit installation option is 020010-100000- 200000-300000.
– Individual control of a remote control(SEG20) is the function that controls an indoor unit individually when there is more than one indoor
unit.
3 Set the indoor unit option by wireless remote control.
02 series installation option
SEG1
SEG2
0
SEG7
SEG8
1
SEG13
SEG14
Use of external
2
control
SEG19
SEG20
Individual control of
3
a remote controller
• When setting the option other than above SEG values, the option will be set as "0".
• SEG5 central control option is basically set as 1 (Use), so you don't need to set the
central control option additionally.
However, if the central control is not connected but it doesn't indicate an error
message, you need to set the central control option as 0 (Disuse) to exclude the
indoor unit from the central control.
• The external output of SEG15 is generated by MIM-B14 connection. (Refer to the
manual of MIM-B14.)
SEG3
2
Evaporator Drying
SEG9
-
Use of hot water heater
SEG15
Setting the output
of external control /
External heater signal
/ Cooling operation
signal / Free Cooling
control signal
SEG21
Heating setting
compensation
SEG4
Use of external
room temperature
sensor / Minimizing
fan operation when
thermostat is off
SEG10
-
SEG16
S-Plasma ion
SEG22
Adjusted EEV step of
stopped unit during oil
return /defrost mode.
SEG5
SEG6
Use of central
FAN RPM
control
compensation
SEG11
SEG12
EEV Step when
heating stops
SEG17
SEG18
Buzzer control
Hours of filter usage
SEG23
SEG24
-
You can connect MIM-B14 to
two female wires at the back
side of the indoor unit.
-
-
25