Emergency Shutdown; Warning Sequence; Shutdown Sequence - Sullair DE-18 Series Operator's Manual And Parts List

Oil-free air compressor 1500 cfm
Hide thumbs Also See for DE-18 Series:
Table of Contents

Advertisement

6.7 EMERGENCY SHUTDOWN

Pressing either E-Stop button will immediately stop
the unit and turn off the power.

6.8 WARNING SEQUENCE

ENGINE WARNING:
ENGINE WARNING: If any of the warning settings
are violated, the "ENG WARNING" light (yellow) on
the panel will flash a code. A decal describing cer-
tain flash codes is attached to the panel door. For
additional flash code description, refer to the
Engine Operator's manual.
COMPRESSOR WARNING:
If any of the warning settings are violated, the
"COMP WARNING" light (yellow) will turn on and
the EMS will display a message.

6.9 SHUTDOWN SEQUENCE

ENGINE SHUTDOWN:
If the CAT ECM shuts down the engine, the mes-
sage "CAT ECM SD" will be displayed on the first
COMPRESSOR OPERATION
line of the EMS. In addition, the "ENGINE SHUT-
DOWN" light located on the panel will flash a code.
A decal describing certain flash codes is attached to
the panel door. For additional flash code descrip-
tion, refer to the Engine Operator's manual.
COMPRESSOR SHUTDOWN:
If any of the compressor shutdown settings are vio-
lated, the EMS will de-energize the CAT ECM and
shut down the engine. The cause of the shut down
will be displayed on the second line of the EMS dis-
play, and the "COMPRESSOR SHTDOWN" light
will come on.
Shutdown/ fault will be displayed on EMS 547
display.
The controller can be reset by pressing and
momentarily holding the RESET pushbutton.
Section 6
29

Advertisement

Table of Contents
loading

Table of Contents