Table 5-1 Program Numbers
PROGRAM NUMBER
S-2
S-4
S-6
S-8
S-10
S-12
S-14
S-16
S-18
S-22
S-23
M-7
S-20
S-30
S-31
Number adjustments are for qualified personnel only. Changing these adjustments could affect operations, and
should be considered dangerous or damaging to equipment and personnel.
*Changing the setting from "YES" to "NO" will maintain engine speed at 1400 RPM, disable loading and
lock out a low P2 shutdown. This feature is needed during inlet depression setting.
ward or backward through the program numbers
until the desired number has been reached. Consult
Table
5-1, Program Numbers.
When the desired program number is displayed,
press the center, "CIRCLE" key. This will again
show the program number and allow another vari-
able to be selected.
Once the controller is in the "PROGRAM
SELECT MODE", the center, "CIRCLE" key is
used to "TOGGLE" between the program num-
bers and their associated, stored values. Each
time the center, "CIRCLE" key is pressed the
alphanumeric display will alternate between the
program number and the value stored in its loca-
tion.
CHANGING SYSTEM VALUES
After the desired program number has been select-
ed and the variable has been displayed, the vari-
able value may be increased or decreased by oper-
ating the UP ARROW key or the DOWN ARROW
DESCRIPTION
P4 OFFSET
P2 OFFSET
P1 OFFSET
P3 OFFSET
T4 OFFSET
T1 OFFSET
T5 OFFSET
T2 OFFSET
T3 OFFSET
Drain open duration
Drain closed duration
Load enabled*
T6 OFFSET
Unload press
Load press
CONTROLLER
RANGE
DEFAULT SETTING
-100-300 PSI
-100-300 PSI
-100-300 PSI
-100-300 PSI
-100-300 °F
-100-300 °F
-100-300 °F
-100-300 °F
-100-300 °F
0-20 seconds
0-600 seconds
NO/YES
-100-300 °F
0-20 PSI
0-20 PSI
key on the front panel.
When the UP ARROW key or DOWN ARROW key
is first pressed, the value displayed will change
by a count of one (1): If the button is held down
continuously, the value will approximately dou-
ble each 0.5 second until released.
RETURNING TO NORMAL DISPLAY FROM PRO-
GRAM SELECT MODE
If no buttons are pressed for two (2) minutes, the
display will automatically revert to the "TITLE
PAGE" display, and the controller will exit from the
"PROGRAM SELECT MODE". The entry code
number must be re-entered to allow access to the
set points.
If immediate return to normal display is desired,
press the DOWN ARROW key until position P-0 (or
S-0) is reached with the message, "CIRCLE TO
EXIT" displayed. When the center, "CIRCLE" key is
pressed, the controller will exit the Program Select
Mode to the "TITLE PAGE" display.
Section 5
0
0
0
0
0
0
0
0
0
3
120
YES
0
5
5
23