F503
Accel/Decel Pattern #2
Program ⇒ Special Control Parameters ⇒ 1 – #4 Settings
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the #2 Accel/Decel
parameter.
Settings:
Linear
S-Pattern 1
S-Pattern 2
Acc/Dec Group
Program ⇒ Special Control Parameters ⇒ Accel/Decel #1 – #4
Parameters
This parameter selects the accel/decel profile to be used during a multiple-
accel/decel profile configuration. The acc/dec setting for selections 1 – 4 may
be found at F009, F500, F510, and F414, respectively.
Acc/Dec Switching Frequency #1
Program ⇒ Special Control Parameters ⇒ Accel/Decel Special
This parameter sets the frequency at which the acceleration control is switched
from the Accel #1 profile to the Accel #2 profile during a multiple-acceleration
profile configuration.
S-Pattern Lower Limit Adjustment
Program ⇒ Special Control Parameters ⇒ Accel/Decel Special
Sets the lower limit of S-pattern 1 and 2.
S-Pattern Upper Limit Adjustment
Program ⇒ Special Control Parameters ⇒ Accel/Decel Special
Sets the upper limit frequency of S-pattern 1 and 2.
G7 ASD Operation Manual
Direct Access Number — F503
Parameter Type — Selection List
Factory Default — Linear
Changeable During Run — Yes
Direct Access Number — F504
Parameter Type — Selection List
Factory Default — 1
Changeable During Run — Yes
Direct Access Number — F505
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 80.0
Units — Hz
Direct Access Number — F506
Parameter Type — Numerical
Factory Default — 25.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 50.0
Units — %
Direct Access Number — F507
Parameter Type — Numerical
Factory Default — 25.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 50.0
Units — %