Table B-1
Types of maintenance for cable kit
Configuration
Building block configuration Unavailable
*1: If there is any physical partition in operation, the crossbar box cannot be powered off.
*2: All physical partitions must be powered off, and the system must be completely shut down.
Maintenance flow
Table B-2 shows the sequence of maintenance work for the cable kit.
Table B-2
Task
1
2
3
4
Enabling Removal of Cable Kit
This section describes preparation for removing the cable kit.
Note - To completely shut down the system, all the power cords must be disconnected.
There is a risk of electrical failure if the power cords are not disconnected.
1.
Log in to the XSCF shell.
2.
Execute the showlogs command to identify the maintenance-target component.
XSCF> showlogs error
For details, see "3.3.5 Checking log information."
3.
Power off all the physical partitions.
For details, see "5.2 Powering Off Physical Partition under Maintenance."
4.
Execute the replacefru command to release the maintenance-target crossbar
backplane unit from the system.
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
138
Active/hot
Active/cold
Unavailable
(*1)
Maintenance flow
Preparation
Removing cable kit
Installing cable kit
Restoring system
Inactive/hot
Inactive/cold
Unavailable
Unavailable
(*1)
Replacement
Enabling Removal of Cable Kit
Removing Cable Kit
Installing Cable Kit
Restoring System
System-stopped
Available (*2)