Grizzly EXTREME Series Manual page 6

Parallelogram jointer
Hide thumbs Also See for EXTREME Series:
Table of Contents

Advertisement

SECTION 2: POWER SUPPLY
Availability
Electrocution,
equipment damage may
occur if machine is not
correctly grounded and
connected to the power
supply.
Full-Load Current Rating
Full-Load Current Rating at 120V ..... 15 Amps
Full-Load Current Rating at 240V .... 7.5 Amps
Circuit Information
For your own safety and protection of
property, consult an electrician if you are
fire,
or
unsure about wiring practices or electrical
codes in your area.
Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one
machine will be running at a time. If this machine
will be connected to a shared circuit where mul-
tiple machines will be running at the same time,
consult a qualified electrician to ensure that the
circuit is properly sized for safe operation.
Circuit Requirements for 120V
Nominal Voltage ........................................ 120V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Power Supply Circuit ......................... 20 Amps
Plug/Receptacle ............................. NEMA 5-15
Circuit Requirements for 240V
Nominal Voltage ........................................240V
Cycle ..........................................................60 Hz
Phase ........................................... Single-Phase
Power Supply Circuit ......................... 15 Amps
Plug/Receptacle ............................. NEMA 6-15
Voltage Conversion

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0604xG0604zxG0604

Table of Contents