2-2-2. VSUB Voltage Adjustment
(Only SNC-CM120)
n
You can check the imprint of CCD used in this adjustment
from the side B of the BI-227 board. Before starting the
procedure, disassemble this unit so that you can check the
BI-227 board and write down the imprinted letter. Be sure
to read the letter from the direction as shown in the picture.
Imprinted letter
. Subject:
None
. Measurement device: Voltmeter
. Specification:
Displayed in the lower portion of
the adjustment software window.
1. Select the letter imprinted on the backside of CCD ("f"
in the above picture), then click the [OK] button.
SNC_CM120
List box
Specificaion
2-4
6
2. Operate the spin box so that the voltage value of the
voltmeter matches the value displayed in the lower
area of the adjustment software window.
SNC_CM120
6
Spin box
3. Click the [OK] button.
4. Check that "OK" is displayed in the upper right area of
the window, and then click the [Next] button.
SNC_CM120
6
SNC-CS20/CM120