RS-232 Host Type Defaults

Three RS-232C hosts are set up with their own parameter default settings
(Table
4-2.). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the
defaults listed below. These defaults take precedence over standard defaults.
So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu
defaults still take precedence.
Parameter
Transmit Code ID
Data Transmission Format
Suffix
Baud Rate
Parity
Hardware Handshaking
Software Handshaking
Serial Response Time-out
Stop Bit Select
ASCII Format
Beep On <BEL>
RTS Line State
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan
bar codes.
Table 4-2. Terminal-Specific RS-232C Defaults
Standard
No
Data as is
CR/LF (7013)
9600
None
None
None
2 Sec.
One
8-Bit
Disabled
Low
ICL
Yes
Data/Suffix
CR (1013)
9600
Even
RTS/CTS
Option 3
None
9.9 Sec.
One
8-Bit
Disabled
High
4-15
FUJITSU
NIXDORF
Mode A/
Mode B
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
None
Odd
None
RTS/CTS
Option 3
None
None
2 Sec.
9.9 Sec.
One
One
8-Bit
8-Bit
Disabled
Disabled
Low
*Low = No
data to send

Advertisement