3.4

Analog current input function parameter list

Pr.
Pr.
group
73
T000
Analog input selection
74
T002
Input filter time constant
241
M043
Analog input display unit switchover
242
T021
Terminal 1 added compensation amount (terminal 2/ Terminal 40)
325
T070
Terminal 40 input selection
849
T007
Analog input offset adjustment
C2(902)
T200
Terminal 2/ Terminal 40 frequency setting bias frequency
C3(902)
T201
Terminal 2/ Terminal 40 frequency setting bias
125(903)
T202
Terminal 2/ Terminal 40 frequency setting gain frequency
C4(903)
T203
Terminal 2/ Terminal 40 frequency setting gain
Name
Setting
Minimum
range
increments
0 to 7, 10 to 17
1
0 to 8
1
0, 1
1
0 to 100%
0.1%
0, 1
1
0 to 200%
0.1%
0 to 590Hz
0.01Hz
0 to 300%
0.1%
0 to 590Hz
0.01Hz
0 to 300%
0.1%
ANALOG CURRENT INPUT
Initial
value
FM
CA
1
1
0
100%
1
100%
0Hz
0%
60Hz
50Hz
100%
3
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8an