2. General Description

Please follow all instructions in this manual to ensure the trouble-free ope-
ration of the FHG flow meters. Omega does not assume responsibility or
liability for damages resulting from noncompliance with these instructions.

3. FHG Flow Meter Selection

For the trouble-free, safe, and reliable operation of the flow meters, se-
lecting the correct type and size is critical. Because of the wide variety of
applications and flow meter designs, the technical data in the Omega cata-
log are general in nature. Certain properties of the devices are dependent

4. Declaration of Conformity

Flow meters of the "FHG" series have been tested for their electromagnetic
compatibility and interference emissions as outlined by the EMC Directive
and are in compliance with the applicable statutory EMC Directives.
They cannot be operated independently, are connected by cable to a po-
wer source, and provide digital electrical signals for electronic evaluation.
All flow meters have a declaration of conformity, which can be requested
if necessary.

5. General Operating Requirements

Before assembly, commissioning or operation, check and verify the following
properties & aspects of the respective circumstances of your system to ensure
operation is trouble-free, safe, and reliable.
1. The Fluid to be Processed
Are the flow meter seals and materials compatible with for the fluid and any cleaning agents that will be used?
Is the fluid viscous or abrasive? Have you properly sized the meter and selected appropriate bearing materials?
Is the fluid dirty or does it contain contaminants/pollutants and solid particles that may require filtration?
Does the fluid have fillers or other additives? What grain sizes do these solids have, and could they block the measuring element?
Is it necessary to install an upstream hydraulic filter (see filtering requirements in section 22 of this document)?
Are tubes and pipes clean and free of assembly residues such as chips, weld spatter?
Is the tank clean and is it impossible for impurities or foreign substances to reach the pipeline or tubing system from the tank?
Is a different fluid used frequently and is the system sufficiently flushed and rinsed in between?
Are pipelines/tubes and the entire system completely deaerated (the system should be slowly filled with fluid before operation at full flow
to avoid hydraulic shock on the mechanical components)?
2. Hydraulic Properties of the System
Is the max. operating pressure of the system less than the max. permissible operating pressure of the flow meter?
Is the max. pressure drop ∆p (at flow meter) below the max. permissible pressure drop?
Is the pressure drop ∆p not excessive with max. flow (e.g. high viscosity)?
Does the flow range of the flow meter (dependent on the viscosity) correspond with the present flow?
Please note that the flow range is less with higher viscosity!
Does the temperature range of the flow meter correspond with the present max. temperature of the fluid?
Is the cross-section of the pipelines/tubes large enough and are there no overly large pressure drops in the system?
Is the hydraulic connection (inlet/outlet) connected corrected and sealed properly?
Note: A blocked flow meter can stop the entire flow. Does the system feature an overpressure / bypass valve? This valve must be checked and
maintained at regular intervals.
4
The device may only be opened within the warranty period after consulta-
tion and approval by Omega.
on type, size and measuring range, as well as the liquid to be measured.
Please contact Omega or one of our sales and service representatives for
detailed information about the appropriate flow meter for your particular
application.
Since the electromagnetic compatibility of the entire measuring sys-
tem is also dependent on the installation of the cables, the correct
connection of the shield, and each individual connected device, all
components must comply with the EMC Directive, and the electroma-
gnetic compatibility of the entire system, machine, or system must be
ensured as well.
All flow meters have been tested in accordance with the applicable statuto-
ry EMC Directives of EN 61000-6 and are CE certified. The EC conformity
marking is the CE mark affixed to all flow meters.